A New Approach to Partial Discharge Detection Under DC Voltage: Application to Different Materials
2021
Usability of a new Direct Current Periodic waveform for partial discharge qualification in HVDC systems is exemplified by tests performed on different materials.
Partial discharges behavior under different rectified waveforms
2017
In this work, a previous software used to simulate partial discharges (PDs) under Alternating Current (AC) stress has been modified in order to evaluate the PDs behavior under a voltage stress close to the Direct Current (DC) waveform. By using a full-wave and a half-wave rectifier, the specimen with an air void defects has been subjected to a gradual constant stress. Finally, a capacitive filter has been inserted in order to produce a steadier voltage supply. Simulation results show that under an almost DC waveform, the PDs activity become less compared to AC stress.
Contributed Review: Review of thermal methods for space charge measurement.
2016
The space charge accumulation phenomenon has garnered great interest over the last two decades because of the increased use of direct current in high voltage electrical systems. In this context, a significant relevance has been achieved by the thermal methods, used for solid dielectrics. This paper presents a review of this non-destructive measurement system used for the measurement of space charge. The thermal pulse method, the thermal step method, and the laser intensity modulation method are described. For each configuration, the principle of operation, the thicknesses analyzed, and the spatial resolution are described, reporting also the main related applications
Space Charge Measurement under DC and DC Periodic Waveform
2018
In High Voltage systems, Partial Discharges (PDs) monitoring are one of the main diagnostic instrument to evaluate the reliability of the apparatus. Under Alternating Current (AC) stress, PDs detection and recognition techniques are well consolidated. On the contrary, the monitoring of PDs under Direct Current (DC) stress is difficult due to complexities related to the nature of the phenomenon, which cause the beginning of PDs events in proximity of the dielectric breakdown. This problem has been partially overcome by using a continuous Periodic waveform (DCP) with positive average value, as described in a recent published work. Under DC stress, another degradation factor is the Space Charg…
2018
Damping distances of surface plasmon polariton modes sustained by different thin titanium nitride (TiN) films are measured at the telecom wavelength of 1.55 μm. The damping distances are correlated to the electrical direct current resistivity of the films sustaining the surface plasmon modes. It is found that TiN/Air surface plasmon mode damping distances drop non-linearly from 40 to 16μm as the resistivity of the layers increases from 28 to 130μΩ.cm, respectively. The relevance of the direct current (dc) electrical resistivity for the characterization of TiN plasmonic properties is investigated in the framework of the Drude model, on the basis of parameters extracted from spectroscopic ell…
Effect of Polarity Reversal on the Partial Discharge Phenomena
2020
In the field of High Voltage Direct Current (HVDC) transmission, the space charge accumulation phenomenon and the Partial Discharges (PD) phenomena are considered the main causes of dielectric ageing. During the years, the degradation effect of both phenomena under constant DC stress has been widely studied by several researchers. In case of polarity reversal, typically carried out to control bi-directional power flow between interconnected High Voltage transmission systems, the space charge movement may not synchronously follow the electric field polarity. This could make the moment of reversing polarity a very critical one, where space charge injected during preceding polarity produces hi…
Review of the PEA Method for Space Charge Measurements on HVDC Cables and Mini-Cables
2019
This review takes into account articles and standards published in recent years concerning the application of the Pulsed Electro Acoustic (PEA) method for space charge measurement on High Voltage Direct Current (HVDC) cables and mini-cables. Since the 80s, the PEA method has been implemented for space charge measurements on flat specimens in order to investigate space charge phenomena and to evaluate the ageing of dielectrics. In recent years, this technique has been adapted to cylindrical geometry. Several studies and experiments have been carried out on the use of the PEA method for full size cables and HVDC cable models. The experiments have been conducted using different arrangements of…
Novel Wood Resistance Measurement Method Reducing the Initial Transient Instabilities Arising in DC Methods Due to Polarization Effects
2019
A novel method for measuring the electrical resistance in wood is presented. It is based on applying an Alternating Current (AC) to two electrodes rammed into the wood. The method reduces the transient time for value stabilization. In case of Direct Current (DC) resistance measurement methods, typically used in wood measurement, an initial transient exists, invalidating the measured value during an initial transient period. This measurement method uses an electronic circuit based on a relaxation oscillator where the wood automatically sets the oscillation frequency depending on its electrical resistance. Compared to other AC methods, this circuit greatly simplifies the measurement process, …
High-definition transcranial direct current stimulation to both primary motor cortices improves unimanual and bimanual dexterity.
2017
While most research on brain stimulation with transcranial direct current stimulation (tDCS) targets unimanual motor tasks, little is known about its effects on bimanual motor performance. This study aims to investigate the effects of tDCS on unimanual as well as bimanual motor dexterity. We examined the effects of bihemispheric anodal high-definition tDCS (HD-atDCS) on both primary motor cortices (M1) applied concurrent with unimanual and bimanual motor training. We then measured the effects with the Purdue Pegboard Test (PPT) and compared them to a sham stimulation. Between a pretest and posttest, 31 healthy, right-handed participants practiced the PPT on three consecutive days and receiv…
Effects of transcranial random noise stimulation combined with Graded Repetitive Arm Supplementary Program (GRASP) on motor rehabilitation of the upp…
2019
We evaluated the combined use of transcranial random noise stimulation (tRNS) with the Graded Repetitive Arm Supplementary Program (GRASP) in sub-acute ischemic stroke patients suffering from arm impairment. Eighteen ischemic stroke patients with upper limb disability were randomly assigned to either the GRASP + tRNS or GRASP + Sham stimulation group. Fugl-Meyer Assessment-Upper extremity (FMA-UE) was performed to evaluate upper limb impairment before treatment (T0), after the last stimulation (T1) and after 30 days (T2). At T1 and T2, beneficial effects in the tRNS group correlated with better FMA-UE score than sham stimulation group (p < 0.001) and these results did not correlate to st…